Agilent Technologies HDMP-3001 User Manual
Page 98
98
ADDR = 0x1DC-F: Receive Format and Destination Error Counter
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1DC
RX_ FORM_DEST_ERR [7:0]
0x1DD
RX_ FORM_DEST_ERR [15:8]
0x1DE
RX_ FORM_DEST_ERR [23:16]
0x1DF
Fixed 0
R/W
RO
Value
0
after
reset
RX_FORM_DEST_ERR
is the RX Format and Destination Error counter. It is non-resetable except that a
hard or soft reset will clear it. After reaching its max value the counter starts over from zero again.
This counter is incremented by each frame that did not increment any of the RX_FCS_HEC_ERR ,
RX_FIFO_UR_ERR, RX_FIFO_OF_ERR, RX_MIN_ERR or RX_MAX_ERR counters, and
•
In GFP mode, an error is found in the Type, DP, SP or Spare fields and checking of the corresponding
field is enabled.
•
In LAPS mode, an error is found in the Address, Control or SAPI fields and checking of the
corresponding field is enabled.
ADDR = 0x1E0-E3: Receive Out of Sync Error Counter
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1E0
RX_SYNC_ERR [7:0]
0x1E1
RX_SYNC_ERR [15:8]
0x1E2
Fixed 0
0x1E3
Fixed 0
R/W
RO
Value
0
after
reset
RX_SYNC_ERR
is the RX Out of Sync Error counter. It is non-resetable except that a hard or soft reset will
clear it. After reaching its max value the counter starts over from zero again. This counter is only used in
GFP mode and is incremented each time the GFP synchronization state machine transitions from the Sync