98

ADDR = 0x1DC-F: Receive Format and Destination Error Counter

ADDR

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

0x1DC

RX_ FORM_DEST_ERR [7:0]

0x1DD

RX_ FORM_DEST_ERR [15:8]

0x1DE

RX_ FORM_DEST_ERR [23:16]

0x1DF

Fixed 0

R/W

RO

Value

0

after
reset

RX_FORM_DEST_ERR

is the RX Format and Destination Error counter. It is non-resetable except that a

hard or soft reset will clear it. After reaching its max value the counter starts over from zero again.
This counter is incremented by each frame that did not increment any of the RX_FCS_HEC_ERR ,
RX_FIFO_UR_ERR, RX_FIFO_OF_ERR, RX_MIN_ERR or RX_MAX_ERR counters, and

In GFP mode, an error is found in the Type, DP, SP or Spare fields and checking of the corresponding
field is enabled.

In LAPS mode, an error is found in the Address, Control or SAPI fields and checking of the
corresponding field is enabled.

ADDR = 0x1E0-E3: Receive Out of Sync Error Counter

ADDR

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

0x1E0

RX_SYNC_ERR [7:0]

0x1E1

RX_SYNC_ERR [15:8]

0x1E2

Fixed 0

0x1E3

Fixed 0

R/W

RO

Value

0

after
reset

RX_SYNC_ERR

is the RX Out of Sync Error counter. It is non-resetable except that a hard or soft reset will

clear it. After reaching its max value the counter starts over from zero again. This counter is only used in
GFP mode and is incremented each time the GFP synchronization state machine transitions from the Sync
state to the Hunt state.