Agilent Technologies HDMP-3001 User Manual
Page 115
115
RX_SDCC_CLK
RX_LDCC_CLK
RX_SDCC_DATA
RX_LDCC_DATA
t
VSDCFC
t
VLDCFC
Label
Parameter
Min
Typ.
Max
Units
RX_SDCC_CLK
RX_SDCC_CLK frequency
192
kHz
t
VSDCFC
Transition RX_SDCC_DATA from RX_SDCC_CLK low
30
70
ns
RX_LDCC_CLK
RX_LDCC_CLK frequency
576
kHz
t
VLDCFC
Transition RX_LDCC_DATA from RX_LDCC_CLK
30
70
ns
8.9 JTAG Interface Timing
TCK
TDI
TMS
TDO
t
HTDO
t
STDI
t
HTD1
t
STMS
t
HTMS
Label
Parameter
Min
Typ.
Max
Units
TCK
TCK frequency
10
MHz
t
STDI
Setup TDI to TCK high
10
ns
t
HTDI
Hold TDI from TCK high
10
ns
t
STMS
Setup TMS to TCK high
10
ns
t
HTMS
TMS from TCK high
10
ns
t
HTDO
TDO valid from TCK low
15
ns
8.8 DCC Interface Receive Timing
Figure 36. DCC Interface Receive Timing
Figure 37. JTAG Interface Timing