Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name G1_CONSEC_NUM[3:0]

Reserved

Reserved

Reserved

RX_PRDI5

R/W

R/W

R/W

Value

0

1

0

1

0

0

0

0

after
reset

ADDR=0x12F: Receive RDI Monitor

Bits 7-4: G1_CONSEC_NUM [3:0]: These 4 bit registers specify the number of consecutive received G1

bytes which will be monitored to determine if a Path RDI indication is present.

Bits 3-1: Reserved

Bit 0:

RX_PRDI5:

It is used to determine which bits of the G1 byte will be monitored for Path RDI

indication. If set, the HDMP-3001 will use only bit 5 of the received G1 byte. If not, bits 5,6, and 7 of
the received G1 byte will be used.

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

Reserved

Reserved

J1_AVL_D

Reserved

J1_OOF_D

R/W

W1C

W1C

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x130: Receive J1 Delta

Bits 7-3: Reserved

Bit 2:

J1_AVL_D:

It is set when J1 capture is completed. It is cleared when writing a one to it.

Bit 1:

Reserved

Bit 0:

J1_OOF_D:

It is set when J1_OOF changes state. It is cleared when writing a one to it.