beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 72

background image

72

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name J1_READ

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

R/W

R/W

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x12D: Receive J1 Reading Control

Bit 7:

J1_READ:

When J1_READ transitions from 0 to 1, the HDMP-3001 will latch the 64-byte

string it received in the J1 byte and write the byte string to RX_J1[63:0].

Bits 6-0: Reserved

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

J1_MODE

Reserved

R/W

R/W

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x12E: Receive J1 Mode Control

Bits 7-2: Reserved

Bit 1:

J1_MODE:

When J1_MODE = 1, the HDMP-3001 captures the 64 byte string it receives in the J1

byte position that ends with {0D,0A} and writes them to RX_J1[63:0]_[7:0]. When J1_MODE = 0,
the HDMP-3001 captures 64 consecutive J1 bytes from the specified tributary regardless of their
content and writes them to RX_J1[63:0]_[7:0].

Bit 0:

Reserved