6.2.4
Module information parameters specific to the bus (P18x)
Access:
Read only
Parameters
Setting value / Description / Note
Device
Parameter
type
P180
… [-01]
…
… [-07]
PPO TYPE
(PPO Type / Module ID)
SK TU4-PNT
8 bit
0 ... 7
The module ID (see gsdml file) for the slots can be queried with this parameter. Caution:
meaningful values can only be read out with an existing AR.
Possible values:
0 = Empty slot
1 = Reserved slot
2 = DIG-IO, Process data for the TU
3 = PPO3, Process data for the FI
4 = PPO4, Process data for the FI
5 = PPO6, Process data for the FI
6 = PPO1, Process or parameter data for the FI
7 = PPO2, Process or parameter data for the FI
[-01] = Reserved
[-02] = Reserved
[-03] = Slot 3 (FI)
[-04] = Reserved
[-05] = Reserved
[-06] = Reserved
[-07] = Reserved
P181
… [-01]
…
… [-06]
MAC address
(MAC address)
SK TU4-PNT
8 bit
0 ... 255
The Ethernet address (MAC address) can be read out from this parameter.
[-
01] … [-03]
PROFINET identification
[-
04] … [-06]
Manufacturer's address range (NORD: from 03.60.00)
Example:
(00:0E:CF:03:60:00)
P185
… [-01]
…
… [-04]
Present IP address
(Present IP address)
SK TU4-PNT
8 bit
0 ... 255
The present IP address can be read out from this parameter.
This may deviate from the saved address (P160) if the PROFINET IO controller reconfigures the
parameter.
[-
01] … [-04]
IP address
P186
… [-01]
…
… [-04]
Present IP sub-net mask
(Present IP sub-net mask)
SK TU4-PNT
8 bit
0 ... 255
The present IP mask can be read out from this parameter.
This may deviate from the saved mask (P161) if the PROFINET IO controller reconfigures the
parameter.
[-
01] … [-04]
IP mask
NOTE
When activated, the functions Disable Current, Quick Stop, Remote Control and
Acknowledge Error, are available at the (local) terminals. To operate the drive, a High
signal must be present on the digital inputs being used before the drive can be enabled.