PROFINET bus module for NORD frequency inverters SK 200E

54

Subject to technical amendments

BU 0290 GB-4312

Parameters

Setting value / Description / Note

Device

Supervisor

Parameter

set

P741

... [-01]

...

... [-10]

Process data bus Out

(Process data bus out)

SK 2xxE

S

0000 ... FFFF (hex)

This parameter provides information about the actual status word and the actual values that are
transferred via the bus systems.

… [-01 ] = Status word

Status word

... [-02] = Actual value 1 (P543 [-01])

... [-03] = Actual value 2 (P543 [-02])

... [-04] = Actual value 3 (P543 [-03])

... [-05] = Bus I/O Out Bit (P481)

The displayed value depicts all bus Out bit sources
linked with OR.

… [-06 ] = Parameter data Out 1
… [-07 ] = Parameter data Out 2
… [-08 ] = Parameter data Out 3
… [-09 ] = Parameter data Out 4
… [-10 ] = Parameter data Out 5

Data during parameter transfer.

P748

CANopen status

(CANopen status (system bus status))

SK 2xxE

0000 ... FFFF (hex)

or

0 ... 65535 (dec)

Shows the status of the system bus.

Bit 0:

Bit 1:

Bit 2:

Bit 3:

Bit 4:

Bit 5:

Bit 6:

Bit 7:

Bit 8:

Bit 9:

Bit 10:

24V Bus supply voltage

CANbus in "Bus Warning" status

CANbus in "Bus Off" status

Bus module is online

Additional module 1 is online

Additional module 2 is online

The protocol of the CAN module is 0 = CAN / 1 = CANopen

Vacant

"Bootup Message" sent

CANopen NMT State

CANopen NMT State

CANopen NMT State

Bit 10

Bit 9

Stopped
Pre- Operational
Operational

0
0
1

0
1
0

P749

Status of DIP switches

(Status of DIP switches)

SK 2xxE

0000 ... 00FF (hex)

or

0 ... 255 (dec)

This parameter shows the current setting of the FI (

Fig. 3

) DIP switch.

Bit 0:

Bit 1:

Bit 2:

Bit 3:

DIP switch 1

DIP switch 2

DIP switch 3

DIP switch 4

Bit 4:

Bit 5:

Bit 6:

Bit 7:

DIP switch 5

DIP switch 6

DIP switch 7

DIP switch 8