NORD Drivesystems BU0290 User Manual
Page 57

6 Parameters
BU 0290 GB-4312
Subject to technical amendments
57
6.2.3
BUS module information parameters, general (P17x)
Parameters
Setting value / Description / Note
Device
Parameter
type
P170
... [-01]
... [-02]
Present error
(Present fault / error)
SK TU4-PNT
16 bit
0 ... 9999
Actual error present. Further details in Section 7.2 "Error messages".
… [-01 ] = Current module error
… [-02 ] = Last module error
Possible values:
1000 = EEPROM error
1010 = System bus 24V missing
1020 = System bus timeout (see time in P151)
1030 = System bus OFF
Specific to PROFINET IO)
5500 = No Ethernet connection
5501 = Hardware error
P171
... [-01]
...
... [-03]
Software version
(Software version / revision)
SK TU4-PNT
16 bit
0,0 ... 9999.9
This parameter shows the software and revision numbers in the module. Array 03 provides
information about any special versions of the hardware or software A zero stands for the
standard version.
… [-01] = Software version
… [-02] = Software revision
… [-03] = Special version
P172
Configuration
(Configuration)
SK TU4-PNT
16 bit
0 ... 3
The version can be queried in this parameter.
Possible displayed values:
0 = Internal module (SK CU4)
1 = External module (SK TU4)
2 = Bus TB via SPI (SK TU3)