6 Parameters
BU 0290 GB-4312
Subject to technical amendments
59
Parameters
Setting value / Description / Note
Device
Parameter
type
P176
... [-01]
...
... [-25]
Process data Bus In
(process data, Bus In)
SK TU4-PNT
16 bit
-32768 ... 32767
Bus data received from PROFINET IO controller
… [-01] = Bus module outputs
… [-02] = Control word FI 1
… [-03] = Setpoint 1 for FI 1
… [-04] = Setpoint 2 for FI 1
… [-05] = Setpoint 3 for FI 1
… [-06] = Setpoint 4 for FI 1
… [-07] = Setpoint 5 for FI 1
… [-08] = Control word FI 2
… [-09] = Setpoint 1 for FI 2
… [-10] = Setpoint 2 for FI 2
… [-11] = Setpoint 3 for FI 2
… [-12] = Setpoint 4 for FI 2
… [-13] = Setpoint 5 for FI 2
…
… [-25] = Setpoint 5 for FI 4
P177
... [-01]
...
... [-25]
Process data Bus Out
(Process data Bus Out)
SK TU4-PNT
16 bit
-32768 ... 32767
Bus data sent from PROFINET IO controller
… [-01] = Bus module inputs
… [-02] = Status word FI 1
… [-03] = Actual value 1 for FI 1
… [-04] = Actual value 2 for FI 1
… [-05] = Actual value 3 for FI 1
… [-06] = Actual value 4 for FI 1
… [-07] = Actual value 5 for FI 1
… [-10] = Status word FI 2
… [-11] = Actual value 1 for FI 2
… [-12] = Actual value 2 for FI 2
… [-13] = Actual value 3 for FI 2
… [-14] = Actual value 4 for FI 2
… [-15] = Actual value 5 for FI 2
…
… [-25] = Actual value 5 for FI 5