5 PROFINET - Data transfer

BU 0290 GB-4312

Subject to technical amendments

29

5 Communication

5.1 Process data

Control words and setpoints are transferred from the bus master / controller to the SK TU4-

…bus module as

process data and in return, the status word and actual values are sent to the bus master / controller from the
FI. Transfer is carried out cyclically. The bus master / controller can access these process values directly, as
they are stored in the IO area.
The length and structure of the process data is specified via the PPO types during the planning of the
PROFINET network.
The allocation of the values transferred in the setpoint/actual value area of the FI is made via the parameters
P543 to P548 or P543 [-

01]…[-05] and P546 [-01] …[-05]..


5.1.1

Process data structure

The structure of the process data is defined by the PPO type.

5.1.1.1

Pure process data communication

Direction of

transmission

Transmitted data

( 4 Byte )

1st word

2nd word

... to SK TU4

Control word

Setpoint 1

... from the SK TU4

Status word

Actual
value 1

Table 11: PPO 3

Direction of

transmission

Transmitted data

( 8 Byte )

1st word

2nd word 3rd word

4th word

... to SK TU4

Control word

Setpoint
1

Setpoint
2

Setpoint
3

... from the SK TU4

Status word

Actual
value 1

Actual
value 2

Actual
value 3

Table 12: PPO 4

Direction of

transmission

Transmitted data

( 12 Byte )

1st word

2nd word 3rd word

4th word

5th word

6th word

... to SK TU4

Control word

Setpoint
1

Setpoint
2

Setpoint
3

Setpoint
4

Setpoint
5

... from the SK TU4

Status word

Actual
value 1

Actual
value 2

Actual
value 3

Actual
value 4

Actual
value 5

Table 13: PPO 6