Function
0
No response
1
Transfer parameter value (word)
2
Transfer parameter value (double word)
4
Transfer parameter value (array word)
5
Transfer parameter value (array double word)
7
Order cannot be executed (with error number in PWE2)
Table 25 Response labels - Meaning
In the response label "Order cannot be executed" (AK = 7), then an error message is added to the parameter
value (PWE2) of the inverter response. For the meanings of the values transferred, please refer to the
following table.
No.
Meaning
0
Invalid parameter number
1
Parameter value cannot be changed
2
Lower or upper value limit exceeded
3
Incorrect sub-index
4
No array
5
Invalid data type (at present only for SK 700E)
6
Only resettable (only 0 may be written)
7
Description element cannot be changed
9
Description data not present
201
Invalid order element in the last order received
202
Internal response label cannot be depicted
Table 26 Response labels
– Explanation of error numbers for response label = 7
NOTE
Both the order label and the response label are abbreviated as AK. Therefore, care must be