6 Parameters

BU 0290 GB-4312

Subject to technical amendments

49

6.1.3

Supplementary parameters (P5xx)

Parameters

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter

set

P509

Source Control Word

(Source control word)

SK 2xxE

S

0 ... 4

{ 0 }

Selection of the interface via which the FI is controlled.

0 = Control terminals or keyboard control** with the SimpleBox (if (P510)=0), the

ParameterBox or via BUS I/O Bits.

1 = Only control terminals *, the FI can only be controlled via the digital and analog input

signals or via the bus I/O bits.

2 = USS *, the control signals (enable, rotation direction, etc.) are transferred via the RS485

interface, the setpoint via the analog input or the fixed frequencies.

3 = System bus *, the control signals (enable, direction of rotation, ...) are transferred via the

system bus (the field bus module and the frequency inverter communicate via the
system bus). I.e. the setting "3" - "System bus" must be selected in parameter (P509)
for control of the frequency inverter via the field bus.

4 = System bus broadcast *

*)

Keyboard control (SimpleBox, ParameterBox, PotentiometerBox) is disabled,
parameterisation is still possible.

**) If the communication during keyboard control is interrupted (time out 0.5 sec), the

FI will disable without an error message.

NOTE:

For details of the optional bus systems, please refer to the relevant supplementary bus manuals
(BU02x0).

As an alternative to setting the parameter, System Bus can also be selected with DIP switch 3.

P510

... [-01]

... [-02]

Setpoint source

(Setpoint source)

SK 2xxE

S

0 ... 4

{ [-01] = 0 }

{ [-02] = 0 }

Selection of the setpoint source to be parameterised.

… [-01] = Main setpoint source

… [-02] = Subsidiary setpoint source

Selection of the interface via which the FI receives the setpoint.

0 = Auto: The setpoint source is automatically

derived from the setting in the parameter P509
>Control word source<.

1 = Control terminals, digital and analog inputs

control the frequency, including fixed frequencies

2 = USS
3 = System bus
4 = System bus broadcast