NORD Drivesystems BU0290 User Manual
Page 30
PROFINET bus module for NORD frequency inverters SK 200E
30
Subject to technical amendments
BU 0290 GB-4312
5.1.1.2
Process and parameter data communication
The exchange of process and parameter data is possible by selecting the PPO types 1 or 2.
Direction of
transmission
Transmitted data
( 12 Byte )
1st word
2nd word
3rd word
4th word
5th word
6th word
... to SK TU4
Parameter
number and
order label
Parameter
index
Parameter
value HI
Parameter
value LO
Control word
Setpoint 1
... from the SK TU4
Parameter
number and
order label
Parameter
index
Parameter
value HI
Parameter
value LO
Status word
Actual value 1
Table 14: PPO 1
Direction of
transmission
Transmitted data
( 16 Byte )
1st word
2nd word
3rd word
4th word
... to SK TU4
Parameter number and
order label
Parameter index
Parameter value HI
Parameter value LO
... from the SK TU4
Parameter number and
order label
Parameter index
Parameter value HI
Parameter value LO
Direction of
transmission
Transmitted data
( 16 Byte )
5th word
6th word
7th word
8th word
... to SK TU4
Control word
Setpoint 1
Setpoint 2
Setpoint 3
... from the SK TU4
Status word
Actual value 1
Actual value 2
Actual value 3
Table 15: PPO 2