NORD Drivesystems BU0260 User Manual
Page 43
4 Commissioning
BU 0260 GB
Subject to technical amendments
43
STW
SW1
SW2
SW3
DIs
In the following example of a VIPA control, the linking of the objects (status word and actual value) of FI 1 to
those of the CANopen master is illustrated.
4th frequency inverter
Actual value
- PDO in USS Protocol Mode
Sequence in CAN telegram
Indication in word
Index
Sub-index Description
0 0x3001
4
Status
word
(ZSW)
1
0x3003 10
Actual value 1 (IW1)
2
0x3003 11
Actual value 2 (IW2)
3
0x3003 12
Actual value 3 (IW3)
3rd frequency inverter
Actual value
- PDO in USS Protocol Mode
Sequence in CAN telegram
Indication in word
Index
Sub-index Description
0 0x3001
3
Status
word
(ZSW)
1
0x3003 7
Actual value 1 (IW1)
2
0x3003 8
Actual value 2 (IW2)
3
0x3003 9
Actual value 3 (IW3)
Actual PDO value
2nd frequency inverter
Actual value
- PDO in USS Protocol Mode
Sequence in CAN telegram
Indication in word
Index
Sub-index Description
0 0x3001
2
Status
word
(ZSW)
1
0x3003 4
Actual value 1 (IW1)
2
0x3003 5
Actual value 2 (IW2)
3
0x3003 6
Actual value 3 (IW3)
1st frequency inverter
Actual value
- PDO in USS Protocol Mode
Sequence in CAN telegram
Indication in word
Index
Sub-index Description
0 0x3001
1
Status
word
(ZSW)
1
0x3003 1
Actual value 1 (IW1)
2
0x3003 2
Actual value 2 (IW2)
3
0x3003 3
Actual value 3 (IW3)
Gateway