G710
G1000 – Subject to Change Without Notice
MOTORS
Additional
Options
High Inertia Cast Iron Fan (Z)
An optional cast iron motor cooling fan is available.
This fan is used as a mechanical soft start and/or soft
stop. This fan adds inertia to the motor. The high in-
ertia fan can also be used for a fl ywheel effect to store
mechanical energy. This can be helpful in smoothing
rapid load changes. The cast iron fan replaces the stan-
dard plastic motor fan. The motor length is the same
as a brakemotor.
Motor Frame
Fan Inertia J
z
[lb-ft
2
]
71
0.0475
80
0.1140
90
0.2375
100
0.2684
112
0.5653
132
0.9500
Motor Backstop (RLS)
NORD can provide backstops on many motor frames.
A backstop will prevent the motor from rotating in
one direction. A common use is to prevent a motor
from allowing a load to move backwards when power
is removed. A motor brake can also be used for this
same purpose.
?
The allowable direction of rotation
must be specifi ed in the order.
Allowable Shaft Rotation
Clockwise - Back of Motor
Counter Clockwise - Back of Motor
CW
CCW
Build
Build
Motor Size
Backstop Torque
Minimum Speed
Motor Extension
[lb-in]
[rpm]
[in]
80S/L
1150
860
2.52
90S/L
1150
860
2.95
100L
1150
860
3.58
112M
3270
750
3.66
132S/M
3270
750
4.21
160M/L
7880
670
6.57
180MX/LX
7880
670
6.73
200L
9120
630
6.57
225S/M
9120
630
6.57
250M
22130
400
9.84
280S/M
51330
320
11.02