Inverter sk 300e trio, Sk 300e inverter ratings, Selection steps – NORD Drivesystems B1000 User Manual
Page 707: Step 1: inverter selection
www.nord.com
G705
G1000 – Subject to Change Without Notice
MOTORS
Inverter
SK 300E Trio
Basic NORD
Power
240 VAC Input Inverter
480 VAC Input Inverter
Motor
Rating
P
Type
Type
Description
HP/kW
[in]
SK 300E
SK 300E
63 S/4
0.16 / 0.12
5.12
-370-323-B
-550-340-B
63 L/4
0.25 / 0.18
5.12
-370-323-B
-550-340-B
71 S/4
0.33 / 0.25
5.71
-370-323-B
-550-340-B
71/L/4
0.50 / 0.37
5.71
-370-323-B
-550-340-B
80 S/4
0.75 / 0.55
6.5
-550-323-B
-550-340-B
80 L/4
1.00/ 0.75
6.5
-750-323-B
-750-340-B
90 S/4
1.50/ 1.1
7.2
-111-323-B
-111-340-B
90 L/4
2.00/ 1.5
7.2
-151-323-B
-151-340-B
100 L/4
3.00/ 2.2
7.91
-221-323-B
-221-340-B
100 LA/4
5.00/ 3.7
7.91
Not Available
-401-340-B
Type designation SK 300E
Type designation SK 300E
-370-323-B
-370-323-B -550-323-B
-550-323-B -750-323-B
-750-323-B -111-323B
-111-323B -151-323-B
-151-323-B -221-323-B
-221-323-B -550-340-B
-550-340-B -750-340-B
-750-340-B -111-340-B
-111-340-B -151-340-B
-151-340-B -221-340-B
-221-340-B -301-340-B
-301-340-B -401-340-B
-401-340-B
Supply Voltage
Supply Voltage
3 Phase 200-240 VAC +/- 10%, 47-63 Hz
3 Phase 380-480 VAC, -20%/+10%, 47-63 Hz
Motor Rating
Motor Rating
1/2 HP
3/4
1 HP
1 1/2 HP
2 HP
3 HP
3/4 HP
1 HP
1 1/2 HP
2 HP
3 HP
4 HP
5 HP
Rated Output Current Amps [RMS]
Rated Output Current Amps [RMS]
2.2
3
4
5.5
7
9.5
1.6
2.2
3
3.7
5.5
7
9.2
Typical Output Current Amps [RMS]
Typical Output Current Amps [RMS]
3.1
4.2
5.6
7.7
9.8
13.3
2.5
3.1
4.2
5.2
7.7
9.8
12.9
Inverter Ratings
NORDAC SK 300E
Motor Mounted Frequency Inverter
For select HP ratings, NORD can provide a fully programmable,
high performance AC vector frequency inverter mounted on the
motor. This motor mounted inverter:
• Eliminates the need to separately mount & wire the inverter
• Insures inverter/motor compatibility
• Has an IP 55 washdown duty enclosure
• Provides Electronic Motor Overload protection
• Insures smooth constant torque operation down to
2 Hz (check motor thermal limitations)
• Features a unique plug-in construction where the
program stays with the motor, minimizing return to
service time in the event of inverter replacement
SK 300E Inverter Ratings
• 200-240 VAC 3 phase 50/60 Hz input, ½ through 3 HP
• 380-480 VAC 3 phase 50/60 Hz input, 3/4 through 5 HP
• Full range of built-in pre-engineered options available
Selection Steps
1) Choose the SK300E-trio inverter based on motor ratings and input line voltage
2) Select the required Trio Interface (TI)
3) Select the braking resistor if required
4) Select additional customer based I/O if required (SK CU2-STD)
5) Select cover mounted technology unit if required
6) If remote wall mounting is required
7) Select any needed programming tools
Step 1: Inverter Selection