MFC010 Interface Manual

5

1.

Introduction

The MFC010 is a s tand al one s ignal c onverter des igned t o di rectly i nterface t he O PTIMASS and

OPTIGAS f amilies of C oriolis m ass f lowmeters into c ontrol s ystems us ing t he M odbus R TU protocol

where t here i s no r equirement f or t he ex tensive out put c ontrol features provided by more expensive

converter solutions.

The MFC010 performs three primary direct measurements, Mass flow, Density and Temperature. Using

these primary measurements the MFC010 is able t o c alculate an ar ray of s econdary v alues s uch as

Volume Flow, Velocity and Concentration.


Mass Flow

– Mass flow measurement doesn’t come any simpler, once installed just perform a “ Zero

Calibration”, “ Reset” t he “ Totalisers” and aw ay y ou go. W here P rocess noi se i s a nui sance use the

“Measurement T ime C onstant”, “ Low F low T hreshold” and “ Pressure S uppression” features to provide

reliable and repeatable results.


Density

– Using the inverse relationship between the Density of the process product and the oscillation

frequency of the measuring tube, the MFC010 can provide a very accurate and reliable Density reading.

In or der t o m aximise t he ex cellent per formance o f the MFC010 the user s hould per form a dens ity

calibration after installation. T he MFC010 provides two forms of Density Calibration, the simple “Single

Point Calibration” and t he more accurate “Two Point Calibration”. U sing the “Density Averaging” feature

the user can reduce noisy readings caused by process installation and noise. NB. Density measurement

is not available with the OPTIGAS 5000 meters.


Concentration

– Using the “Density” and “Temperature” m easurements t he M FC010 i s c apable of

calculating the concentration of a pr oduct in the process medium, from one of a num ber of pre-defined

industry standards, such as “ °Brix” a nd “ °Baumé”, as w ell as us er def ined m ixtures us ing t he

programmable coefficients. Concentration measurement is a f unction that comes with a c omprehensive

manual and a Coefficient calculation software package which will take the users own process data and

convert it into compatible coefficients to permit the MFC010 to automatically calculate the concentration of

the target process.


Velocity

– Using the measured mass flow and density, the velocity of the product is calculated using the

“Pipe Diameter” setting. By default this is set to the measuring tube internal diameter to calculate the

velocity of the product passing through the sensor, but it can be set to calculate the velocity in a section of

the connecting pipe work.


Process Control

– Where precise process conditions are required, the “Process Control” function can be

used t o det ect adv erse v ariations i n t he “ Density” or “ Temperature” m easurements and, as well as

indicating the condition, it can take one of a num ber of pr edefined ac tions ac cording t o t he us ers

requirements.

2.

Mechanical Installation

Refer t o t he i nstallation gui delines and i nstructions f or m ounting t he s ensor i n t he process pipe work

provided in the handbook on the CD supplied with the sensor.