MFC010 Interface Manual

45

Register No.

Description

3015 / 3016

Concentration 2
- The proportion of the selected product in the solution. The value transmitted is

scaled according to the setting of the “Concentration 2 Function” (see Holding

Register No.1029). When using “% Mass” or “% Volume” the selected product may

be either the solute or the solvent according to the setting of “Concentration 2

Product” (see Holding Register No.1030).

Format : Floating Point
Range : 0.0% to 100.0%

3017 / 3018

Velocity
- The velocity at which the medium is passing through the sensor, determined by the

Volume Flow and the Pipe Diameter (see Holding Register No.3043). The value

transmitted is scaled according to the setting of the “Velocity Units” (see Holding

Register No.1026)
Format : Floating Point
Range : Dependant on the sensor type and selected units

3019 / 3020

Mass Total
- The accumulation of mass flow over time. This totaliser can be reset using the

“Reset Totalisers” command (see Coil Register No.1003). The value transmitted is

scaled according to the setting of the “Mass Total Units” (see Holding Register

No.1022). NB Input register 5001 contains a reading with higher resolution, double

floating point format, for this variable.
Format : Floating Point
Range : -1 x 10

12

to +1 x 10

12

kg

3021 / 3022

Volume Total
- The accumulation of volume flow over time. This totaliser can be reset using the

“Reset Totalisers” command (see Coil Register No.1003). The value transmitted is

scaled according to the setting of the “Volume Total Units” (see Holding Register

No.1023) ). NB Input register 5005 contains a reading with higher resolution, double

floating point format, for this variable.
Format : Floating Point
Range : -1 x 10

9

to +1 x 10

9

m

3

3023/ 3024

Concentration 1 Total
- The accumulation of mass of the concentration product over time. This totaliser

can be reset using the “Reset Totalisers” command (see Coil Register No.1003).

The value transmitted is scaled according to the setting of the “Mass Total Units”

(see Holding Register No.1022) or “Volume Flow Units (see Holding Register 1023).

NB Input register 5009 contains a reading with higher resolution, double floating

point format, for this variable.
Format : Floating Point
Range : -1 x 10

12

to +1 x 10

12

kg or -1 x 10

9

to +1 x 10

9

m

3

3025 / 3026

Concentration 2 Total
- The accumulation of mass of the concentration product over time. This totaliser

can be reset using the “Reset Totalisers” command (see Coil Register No.1003).

The value transmitted is scaled according to the setting of the “Mass Total Units”

(see Holding Register No.1022) or “Volume Flow Units (see Holding Register 1023).

NB Input register 5013 contains a reading with higher resolution, double floating

point format, for this variable.
Format : Floating Point
Range : -1 x 10

12

to +1 x 10

12

kg or -1 x 10

9

to +1 x 10

9

m

3