Appendix f: mfc010 toolbox – KROHNE MFC 010 C Converter User Manual
Page 102
100
MFC010 Interface Manual
Appendix F: MFC010 Toolbox
MFC010 Toolbox i s a c onfiguration, di agnostics and ev aluation t ool f or t he K rohne O PTIMASS and
OPTIGAS flow sensors fitted with the MFC010 Sensor Electronics. The complete Graphical User Interface
provides measurement display, diagnostics information and real time data logging. Use MFC010 Toolbox
to quickly and easily configure your OPTIMASS and OPTIGAS flow sensors for any OEM application and
save your register setup to a file for downloading to several units.
MFC010 Toolbox software is provided with every order including the MFC010 Sensor Electronics.
MFC010 Toolbox also requires:
•
An OPTIMASS or OPTIGAS flow sensor with the MFC010 Sensor Electronics (software version:
2.11 or above);
•
The .NET Framework version 2.0 (can be downloaded during installation);
•
A compatible Serial Port or USB to Serial Port Adaptor;
•
An RS232 to RS485 Converter;
•
An approved Power Supply and required Barrier modules.
Please refer to the help files when connecting the meter to y our P C f or t he f irst t ime & f or det ailed
instructions on using MFC010 Toolbox.
Features of the MFC010 Toolbox include:
•
Easy connection using AutoConnect feature (suitable for point-to-point communication only)
•
Easy c onfiguration of al l nec essary oper ating par ameters using text boxes and dr op-down
menus
•
Loading/Saving the configuration data from/to a file
•
Data Logger t ool al lowing the us er t o r ecord and v iew m easurement dat a f or real time trend
analysis & gain a better understanding of their process and diagnose application problems
•
Modbus Terminal window provides a t elegram edi tor w here us ers c an c onstruct and s end
Modbus telegrams for test purposes