KROHNE MFC 010 C Converter User Manual
Page 67

MFC010 Interface Manual
65
Register No.
Description
3073 / 3074
Concentration Coefficient #9
- One of the coefficients used to extrapolate general concentration values
from the Density and Temperature readings. See Section 8.4 on page 76
for more details.
Format : Floating Point
Range : -90,000,000 to + 90,000,000
Default Value : 0
3075 / 3076
Concentration Coefficient #10
- One of the coefficients used to extrapolate general concentration values
from the Density and Temperature readings. See Section 8.4 on page 76
for more details.
Format : Floating Point
Range : -90,000,000 to + 90,000,000
Default Value : 0
3077 / 3078
Concentration Coefficient #11
- One of the coefficients used to extrapolate general concentration values
from the Density and Temperature readings. See Section 8.4 on page 76
for more details.
Format : Floating Point
Range : -90,000,000 to + 90,000,000
Default Value : 0
3079 / 3080
Concentration Coefficient #12
- One of the coefficients used to extrapolate general concentration values
from the Density and Temperature readings. See Section 8.4 on page 76
for more details.
Format : Floating Point
Range : -90,000,000 to + 90,000,000
Default Value : 0
3081 / 3082
Concentration 1 Offset
- A fixed offset that the user can apply any of the Concentration 1
calculations made by the MFC010. S ee Section 8.4 on page 76 for more
details.
Format : Floating Point
Range : -10% to +10%
Default Value : 0 %
3083 / 3084
User Defined Mass Total Units Scaling
- The scaling factor used for the user defined Mass Total units ( see Holding
Register No. 1022)
. See Section 8.7 on page 77 for more details.
Format : Floating Point
Range : 0.00000001 to 1,000
Default Value : 1