beautypg.com

11 17 (1116): report slave id, Report slave id – KROHNE MFC 010 C Converter User Manual

Page 34

background image


32

MFC010 Interface Manual

6.11

17 (11

16

): Report Slave ID

The Report Slave ID command is useful to retrieve all of the identification information from the system

with one simple short request. The master request telegram should be 4 bytes long and formatted as

follows.

Request

Character

Field

For Example

1

Slave Address

01

16

Request to Slave ID 1

2

Function

11

16

“Report Slave ID”

3

CRC Lo

C0

16

CRC Checksum

4

CRC Hi

2C

16

The M FC010 r esponse t elegram w ill be 57 c haracters l ong (including the two CRC checksum bytes

appended to the telegram) and is structured as follows.

Response

Character

Field

For Example

1

Slave Address

01

16

Response from Slave ID 1

2

Function

11

16

“Report Slave ID”

3

Byte Count

34

16

“No of bytes in Reply “ = 52

4

Device ID

00

16

00 = MFC010

5

Run Indicator

FF

16

0 = Off , FF

16

= On

6

Sensor Type (See Holding Register No. 1012)

7

Sensor Size (See Holding Register No. 1013)

8

Sensor Material (See Holding Register No. 1014)

9 – 20

Software Version - 12 Character ASCII String

21 – 34

Software Number - 14 Character ASCII String

35 – 46

Software Compilation Date - 12 Character ASCII String

47 – 49

MFC010 Serial Number – 24 bit Integer (Most Significant Byte First)

50 – 52

Sensor Serial Number – 24 bit Integer (Most Significant Byte First)

53 - 55

System Serial Number – 24 bit Integer (Most Significant Byte First)

56

CRC Lo

CRC Checksum

57

CRC Hi