Appendix B: Default Programming
The following table provides a list of the programming options and their factory default settings.
Program Option
Factory Default
Program Option
Factory Default
Detector Programming
Not Installed
Relay 1
Alarm
Detector Type
Smoke-Photo
Relay 2
Trouble (fixed)
Detector Verification
Off
Relay 3
Supervisory
Detector Walktest
Yes
Annunciator Terminal Mode
No
Detector PAS
No
Annunciator ACS Mode
No
Detector Presignal
No
UDACT
No
Detector Zone Assign.
000 only
ACS Installed
No
Detector Adj/Noun
none
Onboard DACT
No
Module Programming
Not Installed
Printer-PC
No
Module Type
Monitor
Printer Baud
9600
Module Walktest
Yes
Service Terminal Panel ID
0000
Module Presignal
No
Ring Count
0
Module Zone Assign.
000 only
Primary Phone Type
Touchtone
Module Adj/Noun
none
Secondary Phone Type
Touchtone
Zone 0 Enable
Enabled
DACT Communication
OFF
Zone 1 Enable
Enabled
AC Loss Delay
2
Zone 2 Enable
Enabled
Backup Reporting
First Available
Zone 3 Enable
Enabled
Primary Reporting Style
Report Point
.........................through..........
.....................
Secondary Reporting Style
Report Point
Zone 96 Enable
Enabled
Primary Account Code
0000
Zones 97, 98 & 99
Enabled
Secondary Account Code
0000
Loop Style
Style 4
Primary 24 Hour Test Time
0100
Loop Protocol
LITESPEED
Secondary 24 Hour Test Time
0200
Trouble Reminder
Off
Primary Phone Number
Banner
Secondary Phone Number
Time Format
12 Hr
Primary DACT Format
Ademco Contact ID
Hours Setting
12
Secondary DACT Format
Ademco Contact ID
Minutes Setting
00
ANN-Primary Enabled
No
Second Settings
ANN-Primary Modules Addr. 1 - 8
None
AM-PM Setting
AM
ANN-Secondary Enabled
No
Month Setting
01
ANN-Secondary Modules Addr. 1 - 8
None
Day Setting
01
ANN-S/PG Port
Year Setting
00
ANN-S/PG Baud
9600
Daylight Savings
Enabled
ANN-S/PG Data Bits
7
Month Start Daylight Savings
March
ANN-S/PG Parity
Even
Week Start Daylight Savings
Week 2
ANN-S/PG Stop Bits
1
Month End Daylight Savings
November
ANN-S/PG Offline Timer
60
Week End Daylight Savings
Week 1
ANN-S/PG Printer Supervision
No
Verification
OFF
ANN-80 Piezo Enabled
Yes
PAS Timer
0
ANN-80 Lock Enabled
Yes
Presignal Timer
0
ANN-80 Acknowledge Button Enabled
Yes
Waterflow Retard Timer
0
ANN-80 Silence Button Enabled
Yes
NAC 1, 2, 3 & 4 Enable
Enabled
ANN-80 Reset Button Enabled
Yes
NAC 1, 2, 3 & 4 Silenceable
Yes
ANN-80 Drill Button Enabled
Yes
NAC 1, 2, 3 & 4 Type
Bell
ANN-I/O Point/Zone
Zone
NAC 1, 2, 3 & 4 Sync Type
System Sensor
ANN-I/O Range
00-29
NAC 1, 2, 3 & 4 Autosilence
0
ANN-I/O Active LEDs Only
NAC 1, 2, 3 & 4 Coding
Steady
ANN-RLY Relay 1
Zone 1
NAC 1, 2, 3 & 4 Zones
Zone 000 only
................through.......................
............
NAC 1, 2, 3 & 4 Silence Inhibit
No
ANN-RLY Relay 10
Zone 10
Canadian Option Enabled
No
ANN-LED Point/Zone
Zone
Waterflow Silenceable
No
ANN-LED Alarms/ATS (Alarm, Trbl, Supv)
ATS
MNS Override
No
ANN-LED Range
0 - 9