Yokogawa Wireless Temperature Transmitter YTA510 User Manual
Page 57

<9. General Specifications>
9-4
IM 01C50T02-01E
Table 9.2
Ambient Temperature Effect (/10°C Chang)
Sensor Type
Input Range
A/D Coefficient
°C
°F
T/C
B
100
300
1000
to
to
to
300
1000
1820
212
572
1832
to
to
to
572
1832
3308
± ( 0.530 °C – 0.080 % of reading)
± ( 0.350 °C – 0.021 % of reading )
± ( 0.140 °C)
E
-200 to
1000
-328 to
1832 ± ( 0.035 °C + 0.042 % of abs.reading)
J
-200
0
to
to
0
1200
-328
32
to
to
32
2192
± ( 0.039 °C + 0.020 % of abs.reading)
± ( 0.039 °C + 0.0029 % of reading)
K
-200
0
to
to
0
1372
-328
32
to
to
32
2502
± ( 0.046 °C + 0.020 % of abs.reading)
± ( 0.046 °C + 0.0054 % of reading)
N
-200
0
to
to
0
1300
-328
32
to
to
32
2372
± ( 0.054 °C + 0.010 % of abs.reading)
± ( 0.054 °C + 0.0036 % of reading)
R
-50
200
to
to
200
1768
-58
392
to
to
392
3214
± ( 0.210 °C – 0.032 % of abs.reading)
± ( 0.150 °C)
S
-50
200
to
to
200
1768
-58
392
to
to
392
3214
± ( 0.210 °C – 0.032 % of abs.reading)
± ( 0.150 °C)
T
-200
0
to
to
0
400
-328
32
to
to
32
752
± ( 0.046 °C – 0.036 % of abs.reading)
± ( 0.046 °C)
W3
0
1400
to
to
1400
2300
32
2552
to
to
2552
4172
± ( 0.100 °C + 0.0040 % of reading)
± ( -0.130 °C + 0.020 % of reading)
W5
0
1400
to
to
1400
2300
32
2552
to
to
2552
4172
± ( 0.100 °C + 0.0040 % of reading)
± ( -0.120 °C + 0.020 % of reading)
L
-200
0
to
to
0
900
-328
32
to
to
32
1652
± ( 0.039 °C + 0.020 % of abs.reading)
± ( 0.039 °C + 0.0029 % of reading)
U
-200
0
to
to
0
600
-328
32
to
o
32
1112
± ( 0.046 °C + 0.036 % of abs.reading)
± ( 0.046 °C)
RTD
Pt100
Pt200
Pt500
JPt100
Cu
-200
-200
-200
-200
-70
to
to
to
to
to
850
850
850
500
150
-328
-328
-328
-328
-94
to
to
to
to
to
1562
1562
1562
932
302
± ( 0.015 °C + 0.005 % of reading)
± ( 0.023 °C + 0.005 % of reading)
± ( 0.015 °C + 0.005 % of reading)
± ( 0.015 °C + 0.005 % of reading)
± ( 0.320 °C + 0.120 % of reading)
Ni120
-70 to
320
-94 to
608 ± ( 0.010 °C + 0.005 % of reading)
mV
—
± (0.001mV + 0.0043 % of abs.reading)
ohm
—
± ( 0.040 Ω + 0.0088 % of reading)