CONTREX M-Traverse User Manual
Page 82

3 - 35
The factory defaults for the Batch Control Parameters are found in Table 3-26. To
modify the default parameters refer to Table 3-27. If you are uncertain how to enter a
Control Parameter, review the
Operations: Keypad
section.
Table 3-28 Default Batch Control Parameters
CP
Parameter Name
Parameter Value
CP-26
Batch Format
1
CP-27
Batch Limit
0
CP-28
Batch PreAct Distance
999999
Table 3-29 Entering Batch Control Parameters
CP
Parameter Name
Parameter Value
CP-26
Batch Format
Enter “1” in CP-26 for Follower traverses.
Enter “2” in CP-26 for Lead reel revolutions.
CP-27
Batch Limit
Enter the total number of Follower traverses or Lead
reel revolutions that you want counted.
CP-28
Batch PreAct Dist
Enter a specific preact distance at which to activate the
Batch Done (only if CP-26 is set at “1”).