CONTREX M-Traverse User Manual
Page 182

5 - 35
CP-93
OUTPUT B SEGMENT
Use the Output B Segment (CP-93) parameter to determine what segment of the Follower profile
will activate Output B.
Enter “1” in CP-93 to activate Output B during the constant plateau segment of
the Follower profile.
Enter “2” in CP-93 to activate Output B during the constant plateau and Accel/
Decel segments of the Follower profile.
Enter “3” in CP-93 to activate Output B during the dwell segment of the
Follower profile.
The diagram below illustrates the segments of the Follower profile:
Constant
Pitch
Plateau
Follower Profile
Accel/Decel
Accel/Decel
Dwell
1
2
3
CP-94
OUTPUT B DIRECTION
Use the Output B Direction (CP-94) parameter to specify the direction in which Output B will
operate.
Enter “1” in CP-94 to activate Output B during the forward direction.
Enter “2” in CP-94 to activate Output B during the reverse direction.
Enter “3” in CP-94 to activate Output B during the forward and reverse
directions.
CP-95
OUTPUT B POLARITY
Use the Output B Polarity (CP-95) parameter to specify the voltage polarity at which Output B
will operate.
Enter “0” in CP-95 to activate Output B as Active Low Voltage Level.
Enter “1” in CP-95 to activate Output B as Active High Voltage Level.
MV-99 SOFTWARE CODE REVISION
MV-99 displays the code revision number of the M–Traverse's software (EPROM).
MV-00 SOFTWARE PART NUMBER
MV-00 displays the last four digits of the eight digit part number for the M–Traverse's software
(EPROM). The first four digits are assumed to be “1000”.