CONTREX M-Traverse User Manual
Page 35

2 - 20
Batch Done (J1 pin 14)
The Batch Done output is relay activated (driven low ) when the Batch count is
completed. Refer to Figure 2-25.
NOTE: This is an open-collector relay driver. For specification details, see
Refer-
ences: Appendix A
,
M–Traverse Specifications
. Use an external DC power
supply to power the relays. Free-wheeling diodes are incorporated internally
in the M–Traverse and do not need to be added externally.
Alarm (J1 pin 15)
The Alarm output is relay activated (driven low) if the system's speed is above the
speed alarm setting that has been entered in the High Speed Alarm (CP-23) parameter.
Refer to Figure 2-25.
NOTE: This is an open-collector relay driver. For specification details, see
Refer-
ences: Appendix A
,
M–Traverse Specifications
. Use an external DC power
supply to power the relays. Free-wheeling diodes are incorporated internally
in the M–Traverse and do not need to be added externally.
Profile Direction (J1 pin 16)
The Profile Direction output indicates the commanded direction of the profile.
This output is relay deactivated (driven high) when the profile is commanded to move
forward. This output is relay activated (driven low) when the profile is commanded to
move in reverse. Refer to Figure 2-25.
NOTE: This is an open-collector relay driver. For specification details, see
Refer-
ences: Appendix A
,
M–Traverse Specifications
. Use an external DC power
supply to power the relays. Free-wheeling diodes are incorporated internally
in the M–Traverse and do not need to be added externally.