Appendix d: continued – CONTREX M-Traverse User Manual
Page 184

5 - 37
APPENDIX D: CONTINUED
USER
CODE DESCRIPTION
MIN
MAX DEFAULT
RECORD
UNITS
CP-61
Jog Setpoint
0
30000
50
RPM
CP-62
Direct Analog Command -4095
4095
0
DAC Bits
CP-65
Gain
0
30000
3000
N/A
CP-66
Integral
0
30000
1
N/A
CP-70
Device Address
1
32
1
N/A
CP-71
Baud Rate
1
6
6
Coded
CP-72
Character Format
1
3
2
Coded
CP-73
Control Mask
0
3
0
Coded
CP-79
Keypad Lockout Mask
1
2
1
Coded
CP-90
Output A Segment
1
3
1
Coded
CP-91
Output A Direction
1
3
1
Coded
CP-92
Output A Polarity
0
1
0
Coded
CP-93
Output B Segment
1
3
1
Coded
CP-94
Output B Direction
1
3
1
Coded
CP-95
Output B Polarity
0
1
0
Coded