CONTREX M-Traverse User Manual
Page 154

5 - 7
to move the Follower mechanism to “Home”. Jog can also
be used when you need brief bursts of speed to align the
Follower mechanism. When you activate Jog, the RPMs
increase at the acceleration rate that you specified in
Acceleration/Deceleration (CP-60) until the Jog Setpoint
(CP-61) is achieved. When Jog is terminated, the RPMs
return to zero immediately. The Jog direction is deter-
mined by the Jog Forward/Reverse Input (J4, pins 15,16),
which controls the direction of the Speed Command
Output. The Drive Enable discrete output is active during
the Jog mode.
Jog Setpoint
See Appendix C; CP-61.
Keypad Error
See Appendix C; MV-50.
Lead Frequency
See Appendix C; MV-41.
Lead Job Size
See Appendix C; MV-80.
Lead Position
See Appendix C; MV-43.
Lead PPR Reel
See Appendix C; CP-16.
LED Display
The two digit Parameter Code is displayed in the lower
LED Display. The Parameter Code's value is displayed in
the upper LED display. This value can be up to six digits.
Line Notch Counter
See Appendix C; MV-59.
Max RPM Follower
See Appendix C; CP-19.
Mode of Operation
The method used to operate your system, for example
Direct mode or Follower mode.
Monitor Variables
Monitor Variables (MVs) monitor the performance of the
M–Traverse and the system which the M–Traverse is
controlling. Monitor Variables also confirm the wiring, the
tuning and assist with troubleshooting. MVs can be
accessed at any time during the M–Traverse's operation,
including during Run, Jog and F–Stop. There are four
categories of Monitor Variables: Input Monitoring, Output
Monitoring, Performance Monitoring and Status Monitor-
ing.
Numeric Keys
Use the numeric keys to enter a Parameter Code for either