CONTREX M-Traverse User Manual
Page 172

5 - 25
MV-46 PRODUCT RATE
The M-Traverse calculates the cycle time for the last completed profile (in each direction) and
uses this to determine the Product Rate in profiles (layers) per minute.
MV-47 DAC OUTPUT
The DAC Output displays the present level of the analog speed command output to the motor
drive. The DAC output displays in DAC bits. A value of 4095 indicates a 100% positive output
and a value of -4095 indicates a 100% negative output.
MV-48 TRIM OUTPUT
The Trim Output is the calculated output of the compensation algorithm (gain plus integral). This
value is displays in DAC bits. A value of 4095 indicates a 100% positive output and a value of -
4095 indicates a 100% negative output.
MV-49 POSITION ERROR
The Position Error displays the difference between the current Follower position and the
commanded Follower position. It displays in Follower encoder lines. A positive value indicates
that the Follower is behind the commanded position (lagging) and a negative value indicates that
the Follower is ahead of the commanded position (leading)
MV-50 KEYPAD ERROR
If a Control Parameter entry has been rejected, Keypad Errors will display the reason that it was
rejected. The digit that displays a number “1” is the error. In the example below, “Value Exceeds
Maximum Limit” is the error.
Invalid Code Parameter
Value Exceeds Maximum Limit
Value Below Minimum Limit
Keypad Lockout Enabled
Lockout During Run State or Entry Timeout
Not Used