CONTREX M-Traverse User Manual
Page 175

5 - 28
MV-55 DISCRETE INPUTS - GROUP C
The Discrete Inputs - Group C displays the status of the Home Set, Home Seek, Home Return,
and Batch Reset discrete inputs. The number “1” indicates an open, or logic high level. The
number “0” indicates a closed, or logic low level (shorted to common). In the example below,
“Home Seek” is the open or logic high level.
Home Set
Home Seek
Home Return
Batch Reset
Not Used
Not Used
MV-56 DISCRETE OUTPUTS - GROUP A
The Discrete Outputs - Group A displays the status of the Drive Enable, Batch Done, Alarm,
Profile Direction, At-Home and Output A discrete outputs. The number “1” indicates an inactive
or de-energized (logic high) level. The number “0” indicates an active or energized (logic low)
level. In the example below, “Batch Done” is the inactive or de-energized (logic high) level.
Drive Enable
Batch Done
Alarm
Profile Direction
At-Home
Output A