Jog -30 – CONTREX M-Traverse User Manual
Page 77

3 - 30
JOG
When you activate Jog, the RPM increase at the acceleration rate that you specified in
the Accel/Decel (CP-60) parameter until the Jog Setpoint (CP-61) is achieved. Jog can
only be entered from F-Stop and when Jog is terminated, the Follower mechanism
returns to F-Stop. Jog is used when you need brief bursts of speed to align the
Follower mechanism.
The factory default Jog Control Parameters are found in Table 3-22. To modify these
default parameters, refer to Table 3-23. If you are uncertain how to enter a Control
Parameter, review the
Operations: Keypad
section.
Table 3-24 Default Jog Control Parameters
CP
Parameter Name
Parameter Value
CP-61
Jog Setpoint
50
CP-60
Accel/Decel
5.0
Table 3-25 Entering Jog Control Parameters
CP
Parameter Name
Parameter Value
CP-61
Jog Setpoint
Enter the RPM at which you want your system to
operate when it is in Jog.
CP-60
Accel/Decel
Enter the number of seconds in which you want your
system to accelerate from zero RPM to the Jog Setpoint
speed.