CONTREX M-Traverse User Manual
Page 159

5 - 12
Forward Limit
Reverse Limit
Jog Forward/Reverse
Jog
Discrete Outputs:
Open-Collector Driver
(50 VDC max, 200 mA continuous, 800 mA continuous
total)
Drive Enable
Batch Done
Alarm
Profile Direction
At-Home
Output A
Output B
Speed Command:
+5 to + 15 VDC, Unipolar or Bipolar, isolated output
Auto-range to drive reference level
12 bits resolution
+ 5 VDC Supply:
500 mA, max at 0-25 degrees C ambient
250 mA, max at 25-50 degrees C ambient
Serial Interface:
RS422
300 to 9600 Baud
Full parameter access and control
Power Requirements:
115 /230 - 10% +15% VAC
50/60 Hz
0.25 Amp
Operating Temperature:
0 to 55 degrees C
Humidity:
0 to 90% non-condensing
Physical Dimensions:
1/2 DIN, NEMA 12 panel mount
7.5 inches height
3.9 inches width
6.0 inches depth
Weight
5 pounds, 6 ounces