Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 99

Extended System-Level Command Functions
Class Series 2 Programmer’s Manual
85
(NS) Disable Symbol Set Selection – This command prevents the
commands from changing the default single-byte symbol set. When enabled, DPL
Symbol Set commands are ignored.
When enabled, the only way to change the current symbol set is with the
command.
(OF) Option Feedback Mode – This command configures the printer to output the
status of the RFID or Scanner option to the active port, as follows.
Value
Option Feedback Mode Units / Interpretation
D, Rx, S
D
= Disable
Rx
=
RFID Enable, where x is the response format:
A = ASCII
H = Hexadecimal
S
= Scanner
Enable
Table 5-6: Option Feedback Command
Not supported on the I-4208 printer.
Once enabled, the printer will report information about the results of the last label
printed. One response per label is returned to the host (this includes each voided and
retried label). The format and contents of the returned information is as follows: