Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 98

Extended System-Level Command Functions
84
Class Series 2 Programmer’s Manual
Value
Parameter
Interpretation
Default Value
*
Z xxx.xxx.xxx.xxx
Is the DNS2 Address, where:
x = 0 to 9
000.000.000.000
$ xxxxxx
Sets the webpage password, where:
x = alphanumeric characters
sysadm
* Prior to the introduction of WiFi, 192.0.0.192 was the IP default value and the Subnet
Mask was 0.0.0.0.
Table 5-5: Network Setup
Each octet must be zero-filled to be properly interpreted (e.g., an IP Address of
10.12.0.243
must be sent to the printer as 010.012.000.243).
Example:
The command string above is typical of a network setup string (where the values
meanings are shown in the following table). This configuration setup command string
may be included with any other Kc sub-commands.
Sub-commands and Values
Interpretation
NTI010.012.000.243
IP Address: 10.12.0.243
NTS255.255.000.000
Subnet Mask: 255.255.0.0
NTG010.012.254.254
Gateway Address: 10.12.254.254
NTDN
DHCP is disabled
(NR) No Reprint – This command controls the label reprint function following the
correction of a fault condition. Upon detection of a fault (ribbon out, paper out, etc.),
printing stops and a fault indicator is illuminated. After the problem is corrected, the
FEED Key must be pressed to clear the fault and resume normal operation. When
enabled, the label in process is not reprinted.