Extended System-Level Command Functions

Class Series 2 Programmer’s Manual

43

STX Kc

Configuration Set

This command specifies the Power-up Configuration parameter values for the printer and
is equivalent to using other system commands followed by the U. This command
is intended for easily configuring a custom setup, but NOT for dynamic

configuration changes. Configuration commands are examined for differences
relative to the current configuration, and have no impact when no differences exist.

Display-equipped models will reset upon completion of a command stream containing
parameter value changes, while non-display models reset only for certain functions,
such as memory allocation. In any case, no commands should be sent to the printer

until this reset is complete. Other command highlights include the following:

These parameter values are equivalent to changing the respective menu settings and
do not affect the factory default settings of the printer.

If separated by a semi-colon (;), multiple parameter values may be sent in a single
command stream; see sample below.

All values are stored in Flash memory and remain in effect until new values are
received or until factory defaults are restored.

If system commands are sent that override the Power-up Configuration value(s), the
Power-up Configuration value(s) will be restored the next time the printer is powered
“On” or is reset.

These parameters are the same as those found in the Setup Menu (non-display
models), or as those found in the Menu System (display-equipped models). The
respective functions are documented in the appropriate Operator’s or Maintenance

Manual. Not all commands are effective on all Class printers.

Illegal or out of range parameter values may have unpredictable results. In addition,
media sensing scaling values, TOF Bias, etc. may not be effective on other same-type

printers due to hardware tolerances.

Syntax:

Kcaa

1

val

1

[;aa

I

val

I

][;aa

n

val

n

]

Where:

aa

1,

aa

I

, aa

n

- Are two letter parameter names.

val

1,

val

I,

val

n

- Are parameter values, with ranges

appropriate for the associated parameter.

Sample:

KcPA120;CL600;STC

The sample above sets the Present Adjust to 120 dots, and the

Sensor Type to Continuous with a label length of six inches.

The following table summarizes (alphabetically by name) different Configuration Set
command parameters, value ranges, command equivalents and applicability. If no
command equivalent is given, or where clarification is required, descriptions immediately

follow the table.