beautypg.com

Datamax-O'Neil Class Series II Programmer’s Manual User Manual

Page 69

background image

Extended System-Level Command Functions






Class Series 2 Programmer’s Manual

55

Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Menu Item (or Number)

(if available)

Command

Equivalent

Present Adjust

[1]

PA

xxx dots

Model specific;

see Appendix K,

and Present Adjust

Fine Tune.

Print Control (8)

N/A

Present Adjust Fine

Tune

PJ

+ / – dots

Dots (model

specific),

see Appendix K.

Print Control

N/A

Present Distance

PD

0 – 400

1/100 inch

Print Control

Kf

Present Sensor

Equipped

PS

A/Y, E, N/D

A or Y = Auto,

E = Enabled,

N or D = Disabled

Printer Options (3)

V

Print Contrast

PC

0 – 64

N/A

Print Control

N/A

Printer Level

PL

000000 – FFFFFF

Hex Codes

System Settings

N/A

(continued)

This manual is related to the following products: