Extended System-Level Command Functions

Class Series 2 Programmer’s Manual

107

Sample:

KHB

The sample above returns results from the last dot check for
the number of elements tested, the number of the bad or

suspect dot(s), the total number of bad or suspect dots, and the
minimum, maximum, and average resistance and variance:


DOTCHECK RESULTS

DOTS TESTED GOOD 830 OF 832
BAD DOT LIST
143
144

TOTAL BAD DOTS: 2

MIN MAX AVG VAR
921 1640 1125 719

The process normally adds a few seconds to the power-up sequence; however, if the

printhead is invalid or extremely damaged, it could take a minute to complete.






STX KJ

Assign Communication Port

(MCL Command)

This command assigns a communication port for specific use. When activating MCL, all

ports are assigned to MCL; this command allows changes to that assignment.

Syntax:

KJpf

Where:

p

- Port ID: P = Parallel

S = Serial (A)

U = USB

N = Ethernet

L = Wireless

A = Serial (B)

f

- Flag:

1 = DPL

0

=

MCL

Sample:

KJN1

The sample above forces the Ethernet port to bypass MCL and
go directly to DPL.