Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 121
Extended System-Level Command Functions
Class Series 2 Programmer’s Manual
107
Sample:
The sample above returns results from the last dot check for
the number of elements tested, the number of the bad or
suspect dot(s), the total number of bad or suspect dots, and the
minimum, maximum, and average resistance and variance:
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
BAD DOT LIST
143
144
TOTAL BAD DOTS: 2
MIN MAX AVG VAR
921 1640 1125 719
The process normally adds a few seconds to the power-up sequence; however, if the
printhead is invalid or extremely damaged, it could take a minute to complete.
STX KJ
Assign Communication Port
(MCL Command)
This command assigns a communication port for specific use. When activating MCL, all
ports are assigned to MCL; this command allows changes to that assignment.
Syntax:
Where:
p
- Port ID: P = Parallel
S = Serial (A)
U = USB
N = Ethernet
L = Wireless
A = Serial (B)
f
- Flag:
1 = DPL
0
=
MCL
Sample:
The sample above forces the Ethernet port to bypass MCL and
go directly to DPL.