Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 273
Appendix J – General Purpose Input Output Port Applications
Class Series 2 Programmer’s Manual
259
Applicator Interface Card (Type 1) GPIO Port (J2) Overview
Pin
Number
Signal
Name
Signal
Direction
Active
Setting
Jumper
Placement
Function /
Description
1
Ground
(Configurable)
Ground
Ground
JMP 7 “On” Printer chassis ground is
used
Open
Open
JMP 7 “Off”
Ground return must be
supplied
2
+5 VDC
(Configurable)
Output
+5 VDC
JMP 8 “On”
Printer +5 VDC is used
(.5 amp max.)
Open
Open
JMP 8 “Off”
+5 VDC must be supplied
3
Start Of
[3]
Input Programmable
N/A
N/A
4
Slew
Label
Input Programmable
5
Pause
Toggle
Input Low
6 Reprint
[2]
Input
Low
7
+24 VDC
(1.0 amp
max.)
Output +24
VDC
8 Ground
Ground
Ground
9
Ribbon
Low
Output Programmable
JMP 9:
Pins 1 & 2
= +5 VDC
– OR –
Pins 2 & 3 =
+24 VDC
When inactive, all output
pins will be pulled up to
the voltage determined
by this jumper setting.
Failure to
configure the card
for the device(s) you
are connecting may
result in damage to
the printer and/or
the applicator.
10
Service
Required
[1]
Output Low
11
End Of
Output Programmable
12
Media
Out
Output Low
13
Ribbon
Out
Output Low
14
Data Ready
(DRDY)
Output Low
15 Spare
Output N/A
N/A
N/A
[1]
Evoked by occurrences listed under “Fault Messages” in the A-Class Operator’s Manual.
[2]
Reprints the last label exactly, with no increment or time stamp changes; use it for error
conditions. Always keeping this signal LOW will result in non-stop printing.
[3]
If active with no current print job, “WAITING FOR DATA” is displayed. Specifying a quantity of 9999
while always keeping this signal “On” will cause non-stop label printing, except in single label mode
(see Imaging Mode, Section 4.2.5 of the A-Class Operator’s Manual), which will cause the printer to
stop between labels.