beautypg.com

Datamax-O'Neil Class Series II Programmer’s Manual User Manual

Page 278

background image

Appendix J – General Purpose Input Output Port Applications

Class Series 2 Programmer’s Manual

264

GPI/O B (J2)
Six unassigned inputs are designed to interface to open-collector outputs. These inputs

require no external pull-ups and blocking diodes allow the use of totem pole outputs from
+4.5 to + 26 VDC. Optical isolators are available to provide isolation. Two print control

interface circuit examples are given below.



For direct inputs –

Use the printer’s +5VDC and Ground to supply

the devices interfacing to the GPI/O B inputs
(as shown, right).

GPI/O B - J2

8

3

12

7

Input 1

Ground

13

Input 2

Input 3

Input 4

6

Input 5

Input 6

2








For electrically-isolated inputs –


To provide galvanic isolation for the GPI/O B

inputs, remove jumper JMP 11 then supply an
external +5VDC source voltage to Pin 1, and

remove jumper JMP 10 then supply an
external Ground to Pin 6 (as shown, right).




1 Vcc

+5 VDC External Source

GPI/O B - J2

8

3

12

7

Input 1

13

Input 2

Input 3

Input 4

Input 5

Input 6

2

Ground

6



Six unassigned outputs are programmable and slew-limited. Optional 10K ohm pull-up

resistors, one for each of the output lines, can be used at either +5 or +24 VDC via jumpers
JMP 2 – 7.

To avoid damage if external pull-up resistors are used (that is, when Jumpers JMP 2 - 7 are

not installed), ensure that the external voltage does not exceed +30VDC.


The table below details the GPI/O B pin assignments, settings and functions:

This manual is related to the following products: