Extended System-Level Command Functions

Class Series 2 Programmer’s Manual

121

STX KuR Read Data from RFID Tag


(Direct Mode – UHF Interface – Hexadecimal Data Only)

This command instructs the RFID device to read data from the tag and then place that

data into a replaceable field. It is expected that the tag transponder is within the read /
write distance of the RFID programming device; otherwise, “Void” will be printed in the

text or bar code label field(s).

Syntax:

KuRaa

Where:

aa

- Field number in which to place the data (must be 01,

02, 03, etc.) matching the order of Label Formatting

command, U.

A 00 value will send the ID to the host with no

printing.

Sample:

L
D11
1911A1801000100 xxxxxxxxxxxxxxxx
U
1A31050002000200 xxxxxxxxxxxxxxxx
U
X
KuR01
Kur02
G

The sample above creates a replaceable text field (01) and bar
code field (02) and then recalls the data from the tag and places it

into the specified fields.

Data should be at least 16 or 24 characters in length.