Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 113

Extended System-Level Command Functions
Class Series 2 Programmer’s Manual
99
(UM) Units of Measure – See
details.
(UT) User Terminator – This command allows word wrapping of long character
strings of commands to the next line in a file, for the purposes of readability only. In
the
terminator. The last command needs to be END, followed by a line terminator (see
the
(VE) Verifier Equipped – This command enables the GPIO for a bar code verifier
(see Appendix J). A (or Y) - automatically senses device presence; if undetected, no
error is generated. E - enables the device, where its presence must be detected;
otherwise, a fault is generated. N or D - disables device detection.
(VT) Verifier Type – This command is reserved for future use.
(WE) WiFi Setup – This command configures the printer for a WiFi connection, as
follows:
Value
Parameter
WiFi Interpretation
Default Value
A
y
Is the SSID (Access Point name),
where:
y = Up to 31 characters, no spaces
MACR
C
x
Is the Channel number (Adhoc only,
country dependent), where:
x = 1 to 14
1
F
x
Is Enable DHCP Fixed Interval
Transmission, where x:
1 = Fixed
0 = Exponential
0
I
xxx.xxx.xxx.xxx
Is the IP Address*, where:
x = 0 to 9
192.168.010.001
L
x
Is the DHCP Acquire Time Limit, where:
x = 0 to 255 seconds
150
(continued)