Extended System-Level Command Functions

Class Series 2 Programmer’s Manual

99

(UM) Units of Measure – See m (metric) or n (imperial) for command
details.



(UT) User TerminatorThis command allows word wrapping of long character
strings of commands to the next line in a file, for the purposes of readability only. In
the Kc string, the command UTON must fall somewhere before the first line
terminator. The last command needs to be END, followed by a line terminator (see
the KcEN command for details).


(VE) Verifier Equipped –
This command enables the GPIO for a bar code verifier
(see Appendix J). A (or Y) - automatically senses device presence; if undetected, no

error is generated. E - enables the device, where its presence must be detected;
otherwise, a fault is generated. N or D - disables device detection.


(VT) Verifier Type This command is reserved for future use.


(WE) WiFi Setup This command configures the printer for a WiFi connection, as
follows:

Value

Parameter

WiFi Interpretation

Default Value

A

y

Is the SSID (Access Point name),

where:

y = Up to 31 characters, no spaces

MACR

C

x

Is the Channel number (Adhoc only,
country dependent), where:

x = 1 to 14

1

F

x

Is Enable DHCP Fixed Interval

Transmission, where x:

1 = Fixed

0 = Exponential

0

I

xxx.xxx.xxx.xxx

Is the IP Address*, where:

x = 0 to 9

192.168.010.001

L

x

Is the DHCP Acquire Time Limit, where:

x = 0 to 255 seconds

150

(continued)