beautypg.com

Datamax-O'Neil Class Series II Programmer’s Manual User Manual

Page 88

background image

Extended System-Level Command Functions





74

Class Series 2 Programmer’s Manual

(NE) Network Configuration – (for firmware version 14.00 and later) This
command configures the printer for an wired or wireless Ethernet connection.


Syntax is:


aa

i

[nnn

1

,vvvv

1

:nnn

2

,vvvv

2

:…,nnn

n

,vvvv

n

:XX[…]YY[…] ];


where:

aa

i

Configuration Group Identifier

[ ]

Group Scope Delimiters

,

Item – Value Delimiter

:

Item – Value Pair Delimiter


nnn

i

,vvvv

i

:

Configuration Item – Value pairs

nnn

i

Decimal Item Numbers from 1 to 9999

,

Decimal Item Number Delimiter

vvvv

i

Item Value (syntax defined later)

:

Item Value Delimiter

XX[…]

Nested Configuration Sub-Group data stream

XX

Sub-Group

Identifier

(1 – N alpha characters)

[ ]

Sub-Group Scope Delimiters

;

Configuration Group Terminator


The value fields can be represented as one of the following types:

Decimal Value

A decimal value string consisting of an optional leading ‘+-‘ character and followed by

decimal numeric characters 0 – 9.

Scientific Notation Value

A numeric value in scientific notation: (+-)nnnn.mmmmE+-XXX.

Hexadecimal Value

A hexadecimal value expressed like ‘0xb9E23c’.

Binary Bit Value

A binary bit value expressed like ‘0b011011’

Boolean Value

A single character from the following set: ‘Y, N, T, F, 0, 1’

String Value

A string of characters delimited by quotes, ‘…’. The ‘\’ acts as the escape character

permitting the following escaped character sequences:

o

\nnewline (0x0a)

o

\rcarriage return (0x0d)

o

\bbackspace

o

\ttab

o

\fform feed

o

\\backslash

o

\’quote

o

\dddddd consists of 3 OCTAL DIGITS

This manual is related to the following products: