Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 41
System-Level Command Functions
Class Series 2 Programmer’s Manual
27
STX Q
Clear All Modules
This command instructs the printer to clear all Flash and DRAM modules (except as
noted); see the corresponding Operator’s Manual for applicable module options. All
stored data will be destroyed.
Syntax:
Will not affect Module Y or the ILPC Font module.
STX q
Clear Module
This command clears the selected Flash or DRAM module. During normal operations if a
module becomes corrupted (identifiable when the printer responds with a “No Modules
Available” message to a
destroyed.
Syntax:
Where:
a
-
Memory module designator; see Appendix K.
Sample:
The sample above clears memory Module A.
Will not affect Module Y or the ILPC Font module.
STX R
Ribbon Saver Control
This command enables the operation of the optional Ribbon Saver. It is the only
command used to control the Ribbon Saver. Its operation is continuous when enabled.
The printer must be set to thermal transfer (ribbon) printing mode then, during
operation, the Ribbon Saver engages automatically, lifting when the minimum amount of
label white space is exceeded.
Syntax:
Where:
x -
Y
- Enabled (Default = Menu selection.)
N
- Disabled
Sample:
The sample above will turn the ribbon saver on.
This command is ignored on non-equipped printers.