Extended System-Level Command Functions



110

Class Series 2 Programmer’s Manual

STX Kp

Module Protection

This command controls memory module protection. When “protected”, a module will

ignore format, downloads and delete commands. This command can be useful to add
data to reserved modules (see Appendix K for a listing of the memory modules). There

are two module types: RAM (volatile) and Flash (non-volatile).

RAM - When protected and if power is cycled or if the printer is reset, the module
state resets to unprotected.

Flash - When protected, the module can be temporarily unprotected; however, if

power is cycled or if the printer is reset, the module state resets to protected.

Syntax:

Kpmf

Where:

m

-

Module ID – Range A to Z (See Appendix K).

f

-

Flag specifying Enable or Disable protection, where:

0 = disable protection; and,

1 = enable protection.

Sample:

KpY0

The sample above disables protection for Module Y; graphics may

now be downloaded to the module and, on subsequent resets,
these graphics will be protected.