Appendix J – General Purpose Input Output Port Applications

262

Class Series 2 Programmer’s Manual

GPI/O A (J1)

Four dedicated inputs are available for control of printer functions. These inputs require
no external pull-ups, are designed to interface to open-collector outputs and accept totem

pole outputs from +4.5 to + 26 VDC. Optical isolators are available to provide isolation. Two
print control circuit examples are given below.


For direct inputs –

Use the printer’s +5VDC and Ground to supply
the devices interfacing to the GPI/O A inputs

(as shown, right).

GPI/O A - J1

3

4

5

6

1

Start of Print

Slew Label

Toggle/Pause

Reprint

Ground


For isolated inputs –

To provide galvanic isolation for the GPI/O A
inputs, remove jumper JMP 9 then supply an
external +5VDC source voltage to Pin 2, and

remove jumper JMP 8 then supply an external
Ground to Pin 1 (as shown, right).


3

4

5

6

2

Start of Print

Slew Label

Toggle/Pause

Reprint

Vcc

+5 VDC External Source

GPI/O A - J1

1 Ground


Seven dedicated outputs are available for control, warning, and error functions. These

open-collector outputs are slew-limited. Optional 10K ohm pull-up resistors, tied to a
common point for use at either +5 or +24 VDC, are available via jumper JMP 1.

To avoid damage if external pull-up resistors are used (that is, without jumper JMP1

installed), ensure that the external voltage does not exceed +30VDC.

The table below details the GPI/O A pin assignments, settings and functions: