System-Level Command Functions

24

Class Series 2 Programmer’s Manual

STX M

Set Maximum Label Length

This command instructs the printer move media this distance in search of the top-of-

form (label edge, notch, black mark, etc.) before declaring a paper fault. A paper fault
condition can occur if this setting is too close (within 0.1 inch [2.54 mm]) to the physical

length of the label. Therefore, it is a good practice to set this command to 2.5 to 3 times
the actual label length used. The minimum value should be at least 5” (127 mm).

Syntax:

Mnnnn

Where:

nnnn

-

Is a four-digit length, 0000-9999, in/100 or mm/10.

Maximum setting is 9999 (99.99 inches or 2540
mm). The default setting is 16 inches/ 406.4 mm.

Sample:

M0500

The sample above sets a maximum travel distance of 5 inches
(unless the printer is in metric mode; see m).





STX m

Set Printer to Metric Mode

This command sets the printer to interpret measurements as metric values (e.g.,
c0100

will equal 10.0 mm). The default is Imperial (see n).

Syntax:

m





STX n

Set Printer to Imperial Mode

This command sets the printer to interpret measurements as inch values (e.g.,
c0100

will equal 1.00 inch), and is the default mode.


Syntax:

n