beautypg.com

Datamax-O'Neil Class Series II Programmer’s Manual User Manual

Page 18

background image

Overview

4

Class Series 2 Programmer’s Manual

Special Instructions

The green check box is intended to alert the user to conventions used within this
text or to notable operating details of the printer.



Typical Data Flow Sequence


The typical data flow sequence is summarized in the following bullets and detailed in the
table below. Printer Commands data is transmitted to the printer as shown in the table from

left to right, top to bottom.

Status commands

Configuration commands

Download commands

Label format

Status commands

Label reprint commands

Memory cleanup

Printer Commands

Description

Notes

A

“Status” commands: Get
Status, Request Memory

Module Storage

Information…

Optional,

bidirectional
communication

required for these

commands.

WG

O220
n
V0

“Configuration”

commands, download
image…

See Kc to
reduce configuration

commands

transferred

D
IApImagenameimage data...data

“Download” commands,

image, fonts…

RAM (temporary) or

Flash (semi-

permanent)

memory.

L

Begin label

Existing label

formats may be
recalled. Label

header records are

not required.

D11

Label Header record

131100000500050Typical text field 01

Label Formatting Data
record –

Object type, orientation,

position, data

Q0001

Label Quantity

E

Label Terminate record

This manual is related to the following products: