beautypg.com

Cleaning the loss/length connectors, Cleaning the output connector, Cleaning the input connector – Atec Fluke-OF-500 User Manual

Page 64

background image

OF-500 OptiFiber Certifying OTDR
Users Manual

54

Cleaning the Loss/Length Connectors

Always clean and inspect fiber connectors before making
connections. Use 99 %-pure isopropyl alcohol and optical-
grade wipes or swabs to clean the connectors as follows:

Cleaning the OUTPUT Connector

1

Touch the tip of a 2.5 mm lint-free foam swab in
alcohol; then touch the swab to an alcohol-soaked
cleaning pad.

2

Push the swab into the adapter; twist it around 3 to 5
times against the endface, then remove and dispose
of the swab.

3

Dry the endface with a dry swab by twisting it around
in the adapter 3 to 5 times.

4

Inspect the connector regularly with a fiber
microscope, such as the Fluke Networks
FiberInspector Video Microscope.

Cleaning the INPUT Connector

Note

Typically, the input connector requires cleaning
only if it has been touched.

1

Remove the connector adapter to expose the
photodiode lens (see Figure 21).

2

Use the method described under "Cleaning the
Output Connector" above to dampen a swab with
alcohol.

3

Twist the damp swab around against the lens 3 to 5
times; then twist a dry swab around against the lens 3
to 5 times.