Specifications

113

Loss/Length Specifications (cont.)

Specification OFTM-5612B

Multimode

Modules

OFTM-5732 Singlemode Modules

Maximum length measurement

5 km of 50

µ

m or 62.5

µ

m multimode

fiber

20 km of 9

µ

m singlemode fiber

Measurement range

1

2 km for Smart Remote and Loopback
modes
20 km for Far End Source mode

2

10 km for Smart Remote and
Loopback modes
60 km for Far End Source mode

2

Length measurement accuracy

±

1.5 m plus

±

2 % of length

±

1.5 m plus

±

2 % of length

Propagation time accuracy

±

15 ns plus

±

2 % of propagation time

±

15 ns plus

±

2 % of propagation time

Output power (nominal)

> -20 dBm minimum; -19.5 dB nominal

> -8 dBm minimum; -7 dBm nominal

Output power stability over 8-hour
period (after 5 minute warmup)

±

0.1 dB at 73 °F (23

o

C)

±

0.1 dB at 73 °F (23

o

C)

Detector type

InGaAs InGaAs