Atec Fluke-OF-500 User Manual
Page 37
Cleaning and Inspecting Fiber Connectors and Adapters
27
Cleaning and Inspecting Fiber
Connectors and Adapters
Always clean and inspect fiber connectors before making
connections. Use 99 %-pure isopropyl alcohol and
optical-grade wipes or swabs to clean fiber connectors as
follows:
W
Caution
See pages 39 and 52 for instructions on cleaning
the tester's OTDR and loss/length connectors.
•
Connector ends: Wipe the end of the ferrule with a
swab or wipe lightly moistened with alcohol. Dry
with a dry swab or wipe.
•
Bulkhead adapters:
1
Touch the tip of a lint-free foam swab to an
alcohol-soaked cleaning pad.
2
Push the swab into the adapter; twist it around
3 to 5 times against the endface, then remove
and dispose of the swab.
3
Dry the endface with a dry, lint-free swab by
twisting it around in the adapter 3 to 5 times.
•
Inspect connectors with a fiber microscope, such as
the Fluke Networks FiberInspector Video Probe
before making connections. See “Using the
FiberInspector Option” on page 46 for details.
•
Periodically clean fiber adapters with a swab and
alcohol. Dry adapters with a dry swab before use.
•
Always cover unused connectors with dust caps or
plugs. Clean dust plugs periodically with a swab or
wipe and alcohol.