beautypg.com

Atec Fluke-OF-500 User Manual

Page 115

background image

Specifications

105

OTDR Specifications for OFTM-561xB Multimode Modules (cont.)

Loss threshold

6

0.2 dB

Distance accuracy

7

±

1 m

±

0.005 % of distance

±

50 % of resolution

±

index of refraction error

Linearity

8

±

0.07 dB/dB

Sampling resolution

3 cm to 50 cm

Reflectance accuracy

9,10

±

4 dB

Optical return loss accuracy

9,10

±

4 dB

Minimum pulse width

850 nm: 4 ns
1300 nm: 8 ns

Real time trace refresh rate

2 updates per second typical

6.

6 dB above the noise floor.

7.

Does not apply to event table.

8.

Not applicable to OTDR tests using the narrowest pulse width (4 ns at 850 nm; 8 ns otherwise).

9.

Not applicable to OTDR tests using the narrowest pulse width (4 ns at 850 nm; 8 ns otherwise).

10.

Not applicable to hidden events. Upper limit of -40 dB reflectance typical at the near end (100 m).

-continued-